SERIES E2000
Gas Feed Systems
Industrial Gas Feed for Chlorine, Sulfur Dioxide or Ammonia
3-Year Limited Warranty
Hastelloy-C Inlet Valves
Solid Machined PVC Construction
|

|
Enchlor Inc. has been manufacturing the highest quality water treatment equipment and instrumentation since 1978. The Enchlor Inc. series E2000 gas feeders offer feed rate sizes from 0.6ppd to 500ppd. The Series E2000 offers multiple system configurations including automatic switchover, remote meters and cylinder or ton container mounting.
Construction
Enchlor Inc. continually strives to produce the longest lasting and most reliable gas chlorination and sulfonation equipment on the market. We believe that this means using only the highest quality materials and most rugged designs. Fine silver and Hastalloy rate vale and inlet valve components provide long life and accurate control. All body parts are machine from solid stock to provide the most durable chlorinator available
Safety
All vacuum operation. Remote ejector and direct cylinder mounting insures the highest degree of operator safety.
Economy
At last a high quality but economical chlorinator. Proof that quality and ?made in America' production does not need to be expensive.
Technical Data
Model Information Code
E2 þ¯ þ¯ þ¯ þ¯`
Gas
C - Chlorine
S - Sulfur Dioxide
A - Ammonia
Vacuum Regulator Mounting
1 - Direct cylinder or manifold mounted
with rate valve
2 - Ton Mounted with rate valve
3 - Direct cylinder or manifold mounted
with remote mounted meter panel
with rate valve
4 - Ton mounted with remote meter
5 - Two direct cylinder or manifold
mounted vacuum regulators,
automatic switchover module,
and remote mounted meter panel
with rate valve
6 - Ton mounted with auto-switchover
Available Gas Rotometers
1 - 0.6ppd( 12g/h )
2 - 1.5ppd (28g/h)
3 - 4 ppd (75 g/h)
4 - 10 ppd (200 g/h)
5 - 25 ppd (0.5 kg/h)
6 - 50 ppd (0.9 kg/h)
7 - 100 ppd (2.0 kg/h)
8 - 250 ppd (5.0 kg/h)
9 - 500 ppd (10.0 kg/h)
Maximum Capacity
1 - 100ppd
2 - 250ppd
5 - 500ppd
Accuracy: within 4% of max rotometer capacity
Operating Range: 20:1, manual, 10:1 automatic
Back Pressure: Maximum back pressure at point of
application for a standard ejector is 140 psig.
For pressures greater than 140 psig, consult factory.
Tubing Connections: 3/8" vacuum and vent
Operating Temperature: Ejector, 35¢ªF to 120¢ªF;
Other components, -20¢ªF to 120¢ªF
The Series E2000 Gas Feeders can be installed a few feet to several hundred feet from the ejector depending on the maximum feed rate and the diameter of the vacuum tubing or piping.
Standard Installation and Spare Parts Kit (included with all of above models)
(10) ten #GAE-LED-111 lead gaskets
(1) one Ammonia bottle for checking connections
(2) two #ORE-VIT-121 nozzle gaskets
(1) one #GAE-VIT-122 ejector seat
(1) one #VRE-456-100 replacement filter
(1) one Operation and Maintenance Manual
*some internal parts have a lifetime warranty